Generation of Synthetic Ct From Mri for Mri-Based Attenuation Correction of Brain Pet Images Using Radiomics and Machine Learning Publisher

Summary: PET/MRI boost? Study generates sCT/ac-maps via LightGBM/radiomics from IR-PETRA/VIBE-Dixon; MAE 60HU, NMAE 1.5%. Research suggests CPU-fast correction. Imaging advance? #MedicalImaging #AttenuationCorrection

Hoseinipourasl A1, 2 ; Hosseinzadeh GA3 ; Sheikhzadeh P4 ; Arabalibeik H5 ; Alavijeh SK2 ; Zaidi H6, 7, 8, 9 ; Ay MR1, 2
Authors

Source: Medical Physics Published:2025


Abstract

Background: Accurate quantitative PET imaging in neurological studies requires proper attenuation correction. MRI-guided attenuation correction in PET/MRI remains challenging owing to the lack of direct relationship between MRI intensities and linear attenuation coefficients. Purpose: This study aims at generating accurate patient-specific synthetic CT volumes, attenuation maps, and attenuation correction factor (ACF) sinograms with continuous values utilizing a combination of machine learning algorithms, image processing techniques, and voxel-based radiomics feature extraction approaches. Methods: Brain MR images of ten healthy volunteers were acquired using IR-pointwise encoding time reduction with radial acquisition (IR-PETRA) and VIBE-Dixon techniques. synthetic CT (SCT) images, attenuation maps, and attenuation correction factors (ACFs) were generated using the LightGBM, a fast and accurate machine learning algorithm, from the radiomics-based and image processing-based feature maps of MR images. Additionally, ultra-low-dose CT images of the same volunteers were acquired and served as the standard of reference for evaluation. The SCT images, attenuation maps, and ACF sinograms were assessed using qualitative and quantitative evaluation metrics and compared against their corresponding reference images, attenuation maps, and ACF sinograms. Results: The voxel-wise and volume-wise comparison between synthetic and reference CT images yielded an average mean absolute error of 60.75 ± 8.8 HUs, an average structural similarity index of 0.88 ± 0.02, and an average peak signal-to-noise ratio of 32.83 ± 2.74 dB. Additionally, we compared MRI-based attenuation maps and ACF sinograms with their CT-based counterparts, revealing average normalized mean absolute errors of 1.48% and 1.33%, respectively. Conclusion: Quantitative assessments indicated higher correlations and similarities between LightGBM-synthesized CT and Reference CT images. Moreover, the cross-validation results showed the possibility of producing accurate SCT images, MRI-based attenuation maps, and ACF sinograms. This might spur the implementation of MRI-based attenuation correction on PET/MRI and dedicated brain PET scanners with lower computational time using CPU-based processors. © 2025 American Association of Physicists in Medicine.
Other Related Docs
11. Deep Adaptive Transfer Learning for Site-Specific Pet Attenuation and Scatter Correction From Multi-National/Institutional Datasets, 2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium# Medical Imaging Conference and Room Temperature Semiconductor Detector Conference (2022)
12. Deep Active Learning Model for Adaptive Pet Attenuation and Scatter Correction in Multi-Centric Studies, 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record# NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors# RTSD 2022 (2021)