Deep-Learning-Based Attenuation Correction For68 Ga-Dotatate Whole-Body Pet Imaging: A Dual-Center Clinical Study; [68Ga-Dotatate Tum Vucut Pet Goruntuleme Icin Derin Ogrenme Tabanli Atenuasyon Duzeltmesi: Cift Merkezli Bir Klinik Calisma] Publisher



Lord MS1 ; Islamian JP1 ; Seyyedi N2 ; Samimi R3 ; Farzanehfar S4 ; Shahrbabki M5 ; Sheikhzadeh P4, 5
Authors

Source: Molecular Imaging and Radionuclide Therapy Published:2024


Abstract

Objectives: Attenuation correction is a critical phenomenon in quantitative positron emission tomography (PET) imaging with its own special challenges. However, computed tomography (CT) modality which is used for attenuation correction and anatomical localization increases patient radiation dose. This study was aimed to develop a deep learning model for attenuation correction of whole-body68Ga-DOTATATE PET images. Methods: Non-attenuation-corrected and computed tomography-based attenuation-corrected (CTAC) whole-body68Ga-DOTATATE PET images of 118 patients from two different imaging centers were used. We implemented a residual deep learning model using the NiftyNet framework. The model was trained four times and evaluated six times using the test data from the centers. The quality of the synthesized PET images was compared with the PET-CTAC images using different evaluation metrics, including the peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), mean square error (MSE), and root mean square error (RMSE). Results: Quantitative analysis of four network training sessions and six evaluations revealed the highest and lowest PSNR values as (52.86±6.6) and (47.96±5.09), respectively. Similarly, the highest and lowest SSIM values were obtained (0.99±0.003) and (0.97±0.01), respectively. Additionally, the highest and lowest RMSE and MSE values fell within the ranges of (0.0117±0.003), (0.0015±0.000103), and (0.01072±0.002), (0.000121±5.07xe–5), respectively. The study found that using datasets from the same center resulted in the highest PSNR, while using datasets from different centers led to lower PSNR and SSIM values. In addition, scenarios involving datasets from both centers achieved the best SSIM and the lowest MSE and RMSE. Conclusion: Acceptable accuracy of attenuation correction on68Ga-DOTATATE PET images using a deep learning model could potentially eliminate the need for additional X-ray imaging modalities, thereby imposing a high radiation dose on the patient. © 2024 The Author.
Other Related Docs
5. Deep Active Learning Model for Adaptive Pet Attenuation and Scatter Correction in Multi-Centric Studies, 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record# NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors# RTSD 2022 (2021)
7. Deep Adaptive Transfer Learning for Site-Specific Pet Attenuation and Scatter Correction From Multi-National/Institutional Datasets, 2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium# Medical Imaging Conference and Room Temperature Semiconductor Detector Conference (2022)
14. Atb-Net: A Novel Attention-Based Convolutional Neural Network for Predicting Full-Dose From Low-Dose Pet Images, 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record# NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors# RTSD 2022 (2021)
15. Deep Learning-Based Automated Delineation of Head and Neck Malignant Lesions From Pet Images, 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference# NSS/MIC 2020 (2020)
19. Standard-Dose Pet Reconstruction From Low-Dose Preclinical Images Using an Adopted All Convolutional U-Net, Progress in Biomedical Optics and Imaging - Proceedings of SPIE (2021)