Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share By
Comparison of Fit Accuracy and Torque Maintenance of Zirconia and Titanium Abutments for Internal Tri-Channel and Externalhex Implant Connections Publisher



Siadat H1 ; Beyabanaki E2 ; Mousavi N3 ; Alikhasi M4
Authors

Source: Journal of Advanced Prosthodontics Published:2017


Abstract

PURPOSE. This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS. Two regular platform dental implants, one with external connection (Branemark, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at a=0.05 of significance. RESULTS. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P < .001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P < .001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P < .001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values. © 2017 The Korean Academy of Prosthodontics.
Other Related Docs
8. Hybrid Implant Abutments: A Literature Review, European Journal of General Dentistry (2021)
10. Do Type and Shape of Scan Bodies Affect Accuracy and Time of Digital Implant Impressions?, European Journal of Prosthodontics and Restorative Dentistry (2020)
11. Effect of Arch Size and Implant Angulations on the Accuracy of Implant Impressions, European Journal of Prosthodontics and Restorative Dentistry (2021)
16. New Dental Implants With Micro-Movement Capability - Biomechanical Evaluation and Evolution, 2021 29th Iranian Conference on Electrical Engineering# ICEE 2021 (2021)