A Deep Neural Network to Recover Missing Data in Small Animal Pet Imaging: Comparison Between Sinogram-And Image-Domain Implementations Publisher



Amirrashedi M1, 2 ; Sarkar S1, 2 ; Ghadiri H1, 2 ; Ghafarian P3, 4 ; Zaidi H5, 6, 7, 8 ; Ay MR1, 2
Authors

Source: Proceedings - International Symposium on Biomedical Imaging Published:2021


Abstract

Missing areas in PET sinograms and severe image artifacts as a consequence thereof, still gain prominence not only in sparse-ring detector configurations but also in full-ring PET scanners in case of faulty detectors. Empty bins in the projection domain, caused by inter-block gap regions or any failure in the detector blocks may lead to unacceptable image distortions and inaccuracies in quantitative analysis. Deep neural networks have recently attracted enormous attention within the imaging community and are being deployed for various applications, including handling impaired sinograms and removing the streaking artifacts generated by incomplete projection views. Despite the promising results in sparse-view CT reconstruction, the utility of deep-learning-based methods in synthesizing artifact-free PET images in the sparse-crystal setting is poorly explored. Herein, we investigated the feasibility of a modified U-Net to generate artifact-free PET scans in the presence of severe dead regions between adjacent detector blocks on a dedicated high-resolution preclinical PET scanner. The performance of the model was assessed in both projection and image-space. The visual inspection and quantitative analysis seem to indicate that the proposed method is well suited for application on partial-ring PET scanners. © 2021 IEEE.
Other Related Docs
7. Deep Adaptive Transfer Learning for Site-Specific Pet Attenuation and Scatter Correction From Multi-National/Institutional Datasets, 2022 IEEE NSS/MIC RTSD - IEEE Nuclear Science Symposium# Medical Imaging Conference and Room Temperature Semiconductor Detector Conference (2022)
9. Deep Active Learning Model for Adaptive Pet Attenuation and Scatter Correction in Multi-Centric Studies, 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record# NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors# RTSD 2022 (2021)
10. A Deep Learning Method for High-Quality Ultra-Fast Ct Image Reconstruction From Sparsely Sampled Projections, Nuclear Instruments and Methods in Physics Research# Section A: Accelerators# Spectrometers# Detectors and Associated Equipment (2022)
14. A Generic, Scalable, and Cost-Effective Detector Front-End Block for Pet, 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference# NSS/MIC 2017 - Conference Proceedings (2018)
15. Atb-Net: A Novel Attention-Based Convolutional Neural Network for Predicting Full-Dose From Low-Dose Pet Images, 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record# NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors# RTSD 2022 (2021)
16. A Multi-Purpose Clinical Pet Scanner With Dynamic Gantry Design, 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record# NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors# RTSD 2022 (2021)
17. Design, Optimization and Performance Evaluation of Bm-Pet: A Simulation Study, Nuclear Instruments and Methods in Physics Research# Section A: Accelerators# Spectrometers# Detectors and Associated Equipment (2019)