Impact of Image Reconstruction Methods on Quantitative Accuracy and Variability of Fdg-Pet Volumetric and Textural Measures in Solid Tumors Publisher Pubmed



Ketabi A1, 2 ; Ghafarian P3, 4 ; Moslehshirazi MA5 ; Mahdavi SR6 ; Rahmim A7, 8 ; Ay MR1, 2
Authors

Source: European Radiology Published:2019


Abstract

Objective: This study aims to assess the impact of different image reconstruction methods on PET/CT quantitative volumetric and textural parameters and the inter-reconstruction variability of these measurements. Methods: A total of 25 oncology patients with 65 lesions (between 2017 and 2018) and a phantom with signal-to-background ratios (SBR) of 2 and 4 were included. All images were retrospectively reconstructed using OSEM, PSF only, TOF only, and TOFPSF with 3-, 5-, and 6.4-mm Gaussian filters. The metabolic tumor volume (MTV) and total lesion glycolysis (TLG) were measured. The relative percent error (ΔMTV and ΔTLG) with respect to true values, volume recovery coefficients, and Dice similarity coefficient, as well as inter-reconstruction variabilities were quantified and assessed. In clinical scans, textural features (coefficient of variation, skewness, and kurtosis) were determined. Results: Among reconstruction methods, mean ΔMTV differed by -163.5 ± 14.1% to 6.3 ± 6.2% at SBR2 and -42.7 ± 36.7% to 8.6 ± 3.1 at SBR4. Dice similarity coefficient significantly increased by increasing SBR from 2 to 4, ranging from 25.7 to 83.4% between reconstruction methods. Mean ΔTLG was -12.0 ± 1.7 for diameters > 17 mm and -17.8 ± 7.8 for diameters ≤ 17 mm at SBR4. It was -31.7 ± 4.3 for diameters > 17 mm and -14.2 ± 5.8 for diameters ≤ 17 mm at SBR2. Textural features were prone to variations by reconstruction methods (p < 0.05). Conclusions: Inter-reconstruction variability was significantly affected by the target size, SBR, and cut-off threshold value. In small tumors, inter-reconstruction variability was noteworthy, and quantitative parameters were strongly affected. TOFPSF reconstruction with small filter size produced greater improvements in performance and accuracy in quantitative PET/CT imaging. Key Points: • Quantitative volumetric PET evaluation is critical for the analysis of tumors. • However, volumetric and textural evaluation is prone to important variations according to different image reconstruction settings. • TOFPSF reconstruction with small filter size improves quantitative analysis. © 2018, European Society of Radiology.
Other Related Docs
15. Combat Harmonization of Image Reconstruction Parameters to Improve the Repeatability of Radiomics Features, 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record# NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors# RTSD 2022 (2021)