Tehran University of Medical Sciences

Science Communicator Platform

Stay connected! Follow us on X network (Twitter):
Share By
Harmonization Based on Quantitative Analysis of Standardized Uptake Value Variations Across Pet/Ct Scanners: A Multicenter Phantom Study Publisher Pubmed



Monsef A1, 2 ; Ay MR1, 2 ; Sheikhzadeh P1, 3 ; Geramifar P4 ; Rahmim A5, 6 ; Ghafarian P7, 8
Authors

Source: Nuclear Medicine Communications Published:2022


Abstract

Objectives This study aimed to measure standardized uptake value (SUV) variations across different PET/computed tomography (CT) scanners to harmonize quantification across systems. Methods We acquired images using the National Electrical Manufacturers Association International Electrotechnical Commission phantom from three PET/CT scanners operated using routine imaging protocols at each site. The SUVs of lesions were assessed in the presence of reference values by a digital reference object (DRO) and recommendations by the European Association of Nuclear Medicine (EANM/EARL) to measure inter-site variations. For harmonization, Gaussian filters with tuned full width at half maximum (FWHM) values were applied to images to minimize differences in SUVs between reference and images. Inter-site variation of SUVs was evaluated in both pre- and postharmonization situations. Test-retest analysis was also carried out to evaluate repeatability. Results SUVs from different scanners became significantly more consistent, and inter-site differences decreased for SUVmean, SUVmax and SUVpeak from 17.3, 20.7, and 15.5% to 4.8, 4.7, and 2.7%, respectively, by harmonization (P values <0.05 for all). The values for contrast-to-noise ratio in the smallest lesion of the phantom verified preservation of image quality following harmonization (>2.8%). Conclusions Harmonization significantly lowered variations in SUV measurements across different PET/CT scanners, improving reproducibility while preserving image quality. © 2022 Wolters Kluwer Health, Inc. All rights reserved.
Other Related Docs
7. Combat Harmonization of Image Reconstruction Parameters to Improve the Repeatability of Radiomics Features, 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference Record# NSS/MIC 2021 and 28th International Symposium on Room-Temperature Semiconductor Detectors# RTSD 2022 (2021)
14. U-Net-Based Suv Calculation in Fdg-Pet Imaging of Mice Brain for Enhanced Analysis, Current Directions in Biomedical Engineering (2023)